NETBUS IE F5H4 - Industrial Ethernet™ Cat.5e

SF/UTP LSZH 4x2x26/7AWG Cat. 5e

Dynamic application, indoor use

P/N: 0502051

 

CONSTRUCTION

Conductor: stranded bare copper wires – sez. 0,14mm² (26/7AWG)

Insulation: foam-skin polyethylene – diam. 0,93mm

Insulation colors: white-blue; blue; white-orange; orange; white-green; green; white-brown; brown

Pairs assembly: cores twisted to pairs

Global assembly: pairs stranded together

Separation: PET tape with overlap

Shielding:

  • L/PET tape with overlap – AL surface outside
  • tinned copper wire braid – nom. coverage 85%

Outer jacket: LSZH FRNC – Blu RAL 5021

Outer diam.: 6,1 (±0,2) mm

Properties

ELECTRICAL AND TRANSMISSION PROPERTIES

Max DC conductor resistance: 142Ω/km

Capacitance C/C (@800Hz): 48 pF/m

Characteristic impedance: 100 Ω (±15%)

Propagation velocity: 75%

Tensione di prova: 0,7 kVac /1 min (core/core); 0,7 kVac /1 min (core/shield)

Insulation resistance: ≥ 5,0 GΩxkm

Operating voltage: 125 V

FIRE PERFORMANCES

Flame retardant acc. with std. IEC 60332-1

Determination of the amount of halogen acid gas acc. with std. EN 50267-2-1 e IEC 60754-1

Determination of degree of acidity of gases acc. with std. EN 50267-2-2 e IEC 60754-2

Smoke density acc. with std. IEC 61034-2

Heat release (approx.): 471 MJ/km (0,130 kWh/m)

OTHER PROPERTIES

Temperature rating: -20°C / +75°C (fixed use); -5°C / +50°C (flexible use)

Min. bending radius: 8 x Ø [mm] (fixed use); 15 x Ø [mm] (flexible use)

Max. pulling force: 50N

Max length (drag chain): 5m

Min. bending radius

Max. pulling force: 100N

Good resistance to saturated hydrocarbons (diesel, kerosene, petrol ether)

Standard reference: EN 50288-2-2; EN 61156-3; EN 50173; ISO/IEC 11801

Technical documents

Technical datasheet

Scroll to Top