CONSTRUCTION
Inner conductor: Flexible bare copper wires
Insulation: PVC Flame Retardant
Insulation color: Red / Black
Element assembly: Insulated cores forming a flat cable

 

Article List

CEAM P/NCONSTRUCTIONNOM. DIMENSION [mm]APPROX. WEIGHT [kg/km]
01030032x0,35mm21,90x3,9013
01030052x0,50mm22,40x4,9019
01030072x0,75mm22,50x5,2027
01030082x1,00mm22,60x5,4028
01030092x1,50mm22,90x5,7039
01030112x2,50mm23,50x7,3059

Properties

ELECTRICAL AND TRANSMISSION PROPERTIES

Max DC conductor resistance: 50Ω/km (0,35mm2) – 39Ω/km (0,50mm2) – 26Ω/km (0,75mm2) – 18Ω/km (1,00mm2) – 13Ω/km (1,50mm2) – 8Ω/km (2,50mm2)

Capacitance C/C (@800Hz): 83 pF/m (0,35mm2) – 92 pF/m (0,50mm2) – 99 pF/m (0,75mm2) – 95 pF/m (1,00mm2) – 106 pF/m (1,50mm2) – 103 pF/m (2,50mm2)

Insulation resistance: ≥ 200MΩxkm

Dielectric test voltage: 2,0 kVac

Operating voltage (Uo/U): 300/300V

OTHER PROPERTIES

Temperature rating: -10°C / +80°C

Min. bending radius: 10 x Ø [mm]

Standard reference: CEI 20-11; CEI 20-29; EN 50575:2014 + A1:2016; EN 60332-1-2/A1:2015; CEI UNEL 35016:2016; EN 13501-6; CEI 64-8;V4:2017

Available length: 100m reel; (upon request) 500/1000m drum